Publication Title
Actuators
Abstract
Actuators intended for human–machine interaction systems are usually designed to be mechanically compliant. Conventional actuators are not suitable for this purpose due to typically high stiffness. Advanced powered prosthetic and orthotic devices can vary their stiffness during a motion cycle and are power-efficient. This paper proposes a novel actuator design that modulates stiffness by means of a flexible beam. A motorized drive system varies the active length of the cantilever beam, thus achieving stiffness modulation. New large deflection formulation for cantilever beams with rolling contact constraints is used to determine the moment produced by the actuator. To validate the proposed solution method, an experiment was performed to measure large static deformations of a cantilever beam with the same boundary conditions as in the actuator design. The experiments indicate excellent agreement between measured and calculated contact forces between beam and roller, from which the actuator moment is determined.
Recommended Citation
dos Santos, Erivelton Gualter and Richter, Hanz, "Design and Analysis of Novel Actuation Mechanism with Controllable Stiffness" (2019). Mechanical Engineering Faculty Publications. 372.
https://engagedscholarship.csuohio.edu/enme_facpub/372
DOI
10.3390/act8010012
Version
Publisher's PDF
Volume
8
Issue
1
Comments
Article #12
This research was funded by the U.S. National Science Foundation, grant number 1544702.